Tegangan Menengah (Medium Voltage= MV), tegangan menengah/MV berkisar 1000 Volt (1 KV) – 36.000 Volt (36 KV). Jenis kabel yang digunakan juga harus mampu digunakan pada tegangan 1 KV – 36 KV. Tegangan Tinggi (High Voltage =HV), Tegangan Tinggi (High Voltage) berkisar 36 KV – 150.000 Volt (150 KV).

The  backbone  of  many  electric  power systems is the medium voltage
distribution  system.  Typically  operating  at  voltages ranging from
2,400  to  34,500 Volts, voltage stress, corona, surges and protection
of  equipment  all  create  unique  challenges  in  design,  equipment
selection,  operation  and  engineering.  This  2  day class takes you
through   the   basics  of  medium  voltage  power  systems  including
components,  equipment,  design  and  operation  problems  as  well as
protection of medium voltage systems.

Perlunya memilih provider training NISBI INDONESIA yang tepat agar pengetahuan kita mengenai LOW AND MEDIUM VOLTAGE tidak salah

TUJUAN TRAINING LOW AND MEDIUM VOLTAGE: ELECTRICAL MAINTENANCE

Dengan mengikuti pelatihan NISBI INDONESIA Peserta dapat berbagi pengetahuan / sharing knowledge mengenai LOW AND MEDIUM VOLTAGE dengan peserta dari perusahaan lain yang bergerak di bidang LOW AND MEDIUM VOLTAGE

MATERI TRAINING LOW AND MEDIUM VOLTAGE: ELECTRICAL MAINTENANCE

  1. INTRODUCTION
  2. MEDIUM VOLTAGE SAFETY
    • Electrocution at Low vs. Medium Voltage, Arc Flash,
    • Qualified Person, Approach Boundaries
  3. TYPES OF MEDIUM VOLTAGE SYSTEMS
    • Utility and Industrial One lines, Reliability Requirements,
    • Overhead and Underground Systems, Regulated Systems
  4. MEDIUM VOLTAGE CABLE
    • Copper vs. Aluminum Design, Voltage Ratings
    • Insulation Ratings, 100%, 133%, 173% Insulation Levels,
    • Shielding Requirements, Electric Fields, Terminating MV
    • Conductors, Orientation of Overhead Lines
  5. MEDIUM VOLTAGE SUBSTATION TRANSFORMERS
    • Core and Coil Design, Aluminum and Copper Windings
    • Tank Construction, Loss Evaluation, Efficiency, Regulation
  6. SPOT NETWORKS
    • Spot Network Design, Network Protectors, Network Protector
    • Relay Operation, Directional Protection Requirements
  7. PARTIAL DISCHARGE
    • Corona, Surface Tracking, Voltage Stress, Sensing Partial
    • Discharge, Component Failure
  8. GROUNDING MEDIUM VOLTAGE SYSTEMS
    • Resistance Grounding, Solid Grounding, Ungrounded Delta
    • Charging Current, Effect of Ground Faults on Delta Voltage
  9. SURGE PROTECTION
    • Lightning and Switching Surges, Classes of Surge Arresters
    • MCOV Ratings – (Maximum Continuous Operating Voltage)
    • TOV – (Maximum Temporary Over Voltage Capability),
    • Protective Characteristics, Surge Arrester Selection, Energy
    • Capability, Effect of Grounding on Arrestor Selection,
    • Insulation Coordination,
  10. CURRENT TRANSFORMER APPLICATIONS
    • Ratings, Selection Process, Accuracy, Saturation, Excitation
    • Curves, Burden Calculation, Momentary Ratings
  11. MEDIUM VOLTAGE CIRCUIT BREAKERS
    • Vacuum, Air, Oil, SF6 Designs, Symmetrical Interrupting
    • Rating, K-Rated Voltage Factor, Close and Latch Capability
  12. RECLOSERS
    • Application on Feeder Circuits, Recloser Settings
    • Continuous Current and Interrupting Ratings
  13. MEDIUM VOLTAGE FUSES
    • Medium Voltage Switches, Load Rating, Close and Latch
    • Rating, Short Time Rating, Expulsion vs. Current Limiting
    • Fuse Characteristics, E and R Rated Fuses, Fuse Cutouts
  14. MEDIUM VOLTAGE PROTECTION CONCEPTS
    • Medium Voltage Protection, Relays, Circuit Breakers, R and
    • E rated Fuses, Short Circuit vs. Overcurrent Protection
  15. DISTRIBUTION FEEDER PROTECTION
    • Protection with Fuses – 300%, Overcurrent Protection with
    • Relays – 600%, Short Circuit Damage Characteristics, Relay
    • “Reachâ€? for End of Line Faults
  16. ROTATING MACHINERY PROTECTION
    • Requirements, Decrement Curves, Thermal Damage Curves,
    • Reactive, Capability Curves, Differential Protection
  17. MEDIUM VOLTAGE MOTOR CONTROLLERS
    • Protection Requirements, Motor Management Relays, Circuit
    • Breaker Protection, Relaying, Class R Rated Fuses
  18. TRANSFORMER PROTECTION
    • ANSI C57 Thru Fault Curves, Impact of Transformer Winding
    • Configuration, Overview of Differential Protection, Inrush and
    • Harmonic Restraint

PESERTA TRAINING LOW AND MEDIUM VOLTAGE: ELECTRICAL MAINTENANCE

Peserta Training Low and Medium Voltage

  • D3  atau  SLTA  yang berpengalaman kerja minimal 3 tahun, dan atau
    setara.
  • Teknisi,   Operator   dan  Supervisor  didalam  bidang  management
    kelistrikan dan atau non teknik.
  • Mereka  yang  dalam  tugasnya  berhubungan dan atau terkait dengan
    materi kursus.

METODE TRAINING LOW AND MEDIUM VOLTAGE: ELECTRICAL MAINTENANCE

Metode penyelenggaraan baik secara training online atau training zoom atau training daring maupun training offline atau training tatap muka :

  • Presentasi
  • Diskusi antar peserta
  • Studi kasus
  • Simulasi
  • Evaluasi
  • Konsultasi dengan instruktur

TRAINER/ INSTRUKTUR

Instruktur yang berkompeten di bidang  LOW AND MEDIUM VOLTAGE
Tim Instruktur NISBI INDONESIA
Kegiatan training dan konsultansi dikelola oleh para tenaga ahli dan instruktur yang berpengalaman dan berkompeten di bidangnya. Ini akan menjadi “kunci” bagi suksesnya aktivitas training dan konsultansi yang dijalankan.Juga menjadi kunci bagi perkembangan perusahaan anda di masa depan.

Karena kompleksnya pelatihan ini, maka dibutuhkan pendalaman yang lebih komprehensif melalui sebuah training.Dan menjadi sebuah kebutuhan akan training provider yang berpengalaman di bidangnya agar tidak membuat peserta menjadi cepat bosan dan jenuh dalam mendalami bidang teknik ini.

JADWAL PELATIHAN 2025

  • BATCH 1 : 13-14 Januari 2025
  • BATCH 2 : 10-11 Februari 2025
  • BATCH 3 : 10-11 Maret 2025
  • BATCH 4 : 14-15 April 2025
  • BATCH 5 : 15-16 Mei 2025
  • BATCH 6 : 12-13 Juni 2025
  • BATCH 7 : 10-11 Juli 2025
  • BATCH 8 : 18-19 Agustus 2025
  • BATCH 9 : 17-18 September 2025
  • BATCH 10 : 16-17 Oktober 2025
  • BATCH 11 : 13-14 November 2025
  • BATCH 12 : 15-16 Desember 2025

TEMPAT PELAKSANAAN PELATIHAN

  • REGULER TRAINING
    • YOGYAKARTA, Hotel Dafam Malioboro
    • JAKARTA, Hotel Amaris Tendean
    • BANDUNG, Hotel Golden Flower
    • SURABAYA
    • BALI, Hotel Ibis Kuta
    • LOMBOK – NTB
  • ONLINE TRAINING VIA ZOOM
  • IN HOUSE TRAINING

Note :

Waktu dan tempat pelaksanaan pelatihan bisa kami sesuaikan dengan kebutuhan peserta.

Investasi Pelatihan :

Investasi pelatihan selama tiga hari tersebut menyesuaikan dengan jumlah peserta (on call). *Please feel free to contact us.

Apabila perusahaan membutuhkan paket in house training, anggaran investasi pelatihan dapat menyesuaikan dengan anggaran perusahaan.

Fasilitas training membuat dan menggunakan rencana pengembangan diri murah :

  • FREE Airport pickup service (Gratis Antar jemput Hotel/Bandara)
  • FREE Akomodasi Peserta ke tempat pelatihan bagi peserta training terupdate
  • Module / Handout training terupdate
  • FREE Flashdisk
  • Sertifikat training teknik komunikasi murah
  • FREE Bag or bagpackers (Tas Training)
  • Training Kit (Dokumentasi photo, Blocknote, ATK, etc)
  • 2xCoffe Break & 1 Lunch, Dinner
  • FREE Souvenir Exclusive